4) Ensure the Name is
Window_011 and the
Window no. is 11.
5) Set Width to 420.
6) Set Height to 300 (272
for the 4.3 in. OIT).
7) To set the background
color to white:
In the Background
group, next to Color
click .
Select the white color
swatch.
Click OK.
(008)
8) In the Popup window group, set Start pos. X to 120 (0 for the 4.3 in. OIT).
9) In the Popup window group, set Start pos. Y to 120 (0 for the 4.3 in. OIT).
10) Click OK.
11) In the Open Window dialog, select Window_11.
12) Click Open.
13) From the File menu choose Save.
Create a Meter in a Popup Window
This example assumes you have created a popup window in a project that is configured to communicate
with a Watlow Controller and that window is open in EZwarePlus.
1) From the Objects
menu, choose Meter
Display.
2) Click the General tab.
3) In Description type
Heat Power.
4) Click Setting
(009)
Silver Series EM OIT 15 Watlow Addendum